Our soow 4 4 4 gauge cable is part of our power cables portable cord line of wire cable.
4 conductor cable ampacity.
Where the number of current carrying conductors in a raceway or cable exceeds three or where single conductors or multi conductor cables are stacked or bundled longer than 24 inches without maintaining spacing and are not installed in raceways the allowable ampacity of each conductor shall be reduced as shown in the following table.
Adjustment factors range from 80 for 4 to 6 conductors all the way to 35 for 41 or more conductors.
Soow 4 4 4 gauge portable and power cable.
Carol super vu tron supreme 250 ft.
7 amps 5 6 amps.
10 amps 7 amps.
Allowable ampacities of insulated copper conductors rated up to and including 2000 volts 60 c through 90 c 140 f through 194 f not more than three current carrying conductors in raceway cable or earth directly buried based on ambient temperature of 30 c 86 f.
The number and type of electrical devices connected to a circuit determine the ampacity requirement of the conductor.
Priority wire cable little rock ar pwc october 31 2019 type w 4 5 conductors 90 c 600 2000v part number size awg kcmil no.
Current is measured in amperes or amps.
For ambient temperatures other than 78 f 86 f or more than three current carrying conductors in a raceway cable or earth use the advanced wire ampacity calculator this takes into account correction factors for voltage drop temperature and the number of current carrying conductors.
Soow 4 4 is composed of 4 bare copper conductors with a 119 25 stranding an ethylene propylene diene monomer rubber epdm insulation and a chlorinated polyethylene cpe jacket.
0 50 ft.
Over 15 2 m soow service oil resistant insulation jacket weather resistant 18 awg.
10 4 600 volt yellow soow portable power cord.
0 15 2 m over 50 ft.
Cord conductors number of current carrying conductors 1 ampacity of current carrying conductors amperes voltage rating of cord.
If there are more than three current carrying conductors the ampacity from the table must be adjusted based on the values found in nec table 310 15 b 3 a.
Conductors are manufactured in accordance with astm and b 172 made in accordance with icea s 75 381 nema wc 58 portable and power feeder cables for use in mines and similar locations msha accepted p 136 135 lr65300 csa or c ul certified as applicable rohs compliant meets ft 5 flame test.
Of conductors conductor strand nominal insulation thickness nominal overall diameter cable weight lbs kft ampacity amps inches mm inches mm 8 04 typew 8 4 133 0 060 1 52 0 97 24 6 656 65.
2 3 or 4 3 or.